91性色福利在线视频,亚洲人妻免费丝袜视频,久久综合久久97综合,蜜桃视频午夜在线观看,偷拍亚洲欧美人妻少妇,亚洲欧美自偷自拍另类视,k频道在线观看国产精品,国产又粗又猛又色又黄在线,国产网友偷拍自拍视频

您好,歡迎來(lái)到維庫(kù)儀器儀表網(wǎng) 網(wǎng)站登錄 | 免費(fèi)注冊(cè) | 忘記密碼

咨詢電話SERVICE LINE

86 0757 22306785

13695162069

商鋪首頁(yè) 公司介紹 公司動(dòng)態(tài) 產(chǎn)品中心 技術(shù)資料 在線留言 聯(lián)系我們
您所在的位置:維庫(kù)儀器儀表網(wǎng) > 手機(jī)/通訊測(cè)試儀 > 佛山市順德區(qū)力揚(yáng)奧特自動(dòng)化設(shè)備公司 > 產(chǎn)品中心 > 供應(yīng)通訊變壓器測(cè)試儀3261A
供應(yīng)通訊變壓器測(cè)試儀3261A
供應(yīng)通訊變壓器測(cè)試儀3261A
  • 供應(yīng)通訊變壓器測(cè)試儀3261A
掃一掃

掃一掃
進(jìn)入手機(jī)店鋪

供應(yīng)通訊變壓器測(cè)試儀3261A

產(chǎn)品價(jià)格:
電議
產(chǎn)品型號(hào):
3261AAB
供應(yīng)商等級(jí):
企業(yè)未認(rèn)證
經(jīng)營(yíng)模式:
工廠
企業(yè)名稱:
佛山市順德區(qū)力揚(yáng)奧特自動(dòng)化設(shè)備公司
所屬地區(qū):
廣東省
發(fā)布時(shí)間:
2011/6/13 16:39:09

86 0757 22306785      13695162069

許軍華先生(聯(lián)系我時(shí),請(qǐng)說(shuō)明是在維庫(kù)儀器儀表網(wǎng)看到的,謝謝)

企業(yè)檔案

佛山市順德區(qū)力揚(yáng)奧特自動(dòng)化設(shè)備公司

企業(yè)未認(rèn)證營(yíng)業(yè)執(zhí)照未上傳

經(jīng)營(yíng)模式:工廠

所在地:廣東省

主營(yíng)產(chǎn)品:測(cè)漏機(jī);合蓋機(jī);檢漏機(jī);自動(dòng)化技術(shù);自動(dòng)化水處理技術(shù);吹瓶機(jī);模內(nèi)貼標(biāo)機(jī);制罐設(shè)備;

產(chǎn)品搜索

手機(jī)訪問(wèn)

掃一掃
進(jìn)入手機(jī)店鋪

品牌wk型號(hào)3261AAB
測(cè)量范圍20 Hz to 3 MHz測(cè)量0.1%
電源電壓1 mV to 10 V(V) 尺寸150*440*520(mm)
重量14(kg) 用途通訊變壓器測(cè)試儀

3261AAB是透過(guò)單一治具,針對(duì)通信變壓器的自動(dòng)測(cè)試儀,搭配3260B精密磁性元件分析儀使用,能量測(cè)插損(IL)及回?fù)p(RL)、縱向平衡及橫向平衡、總諧波失真(THD)這些參數(shù)能透過(guò)3260B精密磁性元件分析儀的圖形選配功能(/G graph option)繪制圖形并可列印輸出。



Telecom Unit - 3261A

Automatically tests telecom transformers in a

production environment

Measures Total Harmonic Distortion, longitudinal

and transverse balance and Insertion Loss and

Return Loss

Fast, accurate and repeatable automatic

measurements

Straightforward intuitive operation

Graph longitudinal and transverse balance, and

insertion and return loss against frequency

Suitable for ADSL, HDSL, ISDN, analog line

matching transformers and POTS splitters

Accurate DC bias current

Low cost compared to comparable equipment

Telecom component characterisation

3261A Telecom Unit forms the core of a comprehensive

component test system. It is configured in conjunction with

the Wayne Kerr 3260B Precision Magnetics Analyzer to

carry out a wide variety of telecom-related measurements.

Telecoms Fixture model 1008 further enhances the test

capability by providing an interface to connect units under

test such as transformers.

Complete telecom transformer

characterization

Automatic production testing of telecom transformers

is available with the 3261A. Transformers are

characterized at the press of a button.

Total Harmonic Distortion

Providing unrivalled Total Harmonic Distortion (THD)

performance this optional function displays the second,

third, fourth and fifth harmonic as well as THD.

Measurements as low as -110 dB can be carried out;

the user can set a large number of preset fundamental

frequencies from 150 Hz to 200 kHz.

Longitudinal balance and transverse

balance

This optional function provides longitudinal balance

and transverse balance measurements in line with

IEEE 455, ITU recommendation O.9 (O.121) and FCC

68.310 over the frequency range 200 Hz to 3 MHz.

Measurement capability is high, longitudinal balance

accuracy is ±1 dB over 80 dB, ensuring that devices

can be measured with confidence.

The longitudinal and transverse balance of any

component can be completely characterized

graphically across the full frequency band enabling

component performance to be analyzed in more detail

Insertion Loss and Return Loss

3261A Telecom Unit measures Insertion Loss and Return

Loss from 20 Hz to 3 MHz on transformers and POTS

splitters.

The instrument can also measure and display many

parameters including Insertion Loss and Return Loss

against frequency in a graphical form - ideal in a design or

development environment.

Swept measurements in graphical form

It is often important to characterize component

performance outside its operating range, especially during

component design. The 3261A allows Insertion Loss,

Return Loss, transverse and longitudinal balance, and the

usual basic transformer parameters, such as Inductance

and interwinding capacitance, to be displayed graphically.

Sweeping the full frequency band for the particular

measurement the user can identify the maximum and

minimum point on the graph and a moveable marker

displays the frequency and level. The graph axes can

be selected as either a logarithmic or linear scale.

Comprehensive test system

The key to the test system’s versatility and accuracy is

the combination of a precision impedance analyzer

with a dedicated telecomms test unit. This

combination provides many advantages.

Where special interface methods are needed the 1008

Telecoms Fixture is available, or customised fixtures

can be configured using a blank fixture to ensure high

integrity measurements.

 

3261A Telecom Unit is the core of a comprehensive test system which also incorporates

3260B Precision Magnetics Analyzer and Telecoms Fixture model 1008

ADSL, ISDN and HDSL analogue line matching

transformers and POTS splitters

ADSL technology requires tighter specifications and

additional measurements when testing line matching

transformers. The 3261A provides all the required

measurements and performance for ADSL technology,

including Total Harmonic Distortion, longitudinal and

transverse balance, Insertion Loss and Return Loss.

It not only exceeds the required specifications but also

makes all the measurements automatically from the same

fixture. For the user it is just a case of connect and test,

ideal in a production environment, with no complex setups,

special jigs or the need to calculate the result from a

number of voltage measurements - the 3261A does it all.

The user is able to select the required line side

termination from a list of predetermined values.

Equipment side terminations are provided by the user

and can be connected to the appropriate socket on the

3261A. Once the termination has been fitted no

further interaction is required by the user.

Accurate DC bias current

DC bias current can be selected for Insertion Loss,

Return Loss and Total Harmonic Distortion.

This function provides high accuracy user selectable

DC current in the range 1 mA to 200 mA in 0.1 mA

steps (to 20 mA) and 1 mA steps (to 200 mA).

The total production test solution ... in a single fixture

Replacing many discrete instruments, complex jigs and

difficult measurements, the 3261A Telecom Unit provides

all the functions needed to meet the new telecom

standards in a single multi-function unit.

It also replaces all the hard work, high skill levels and

uncertainty of manual testing by handling all the complexity

internally and presenting the user with the information

required quickly and accurately. In a production

environment it is just a case of connect and test.

All the user has to do is press the start button and the

3261A Telecom Unit makes all the measurements and

displays a Pass/Fail banner.

Technical specifications

Telecom Unit – 3261A

General

Line side termination: 50, 75, 100, 120, 135, 600, 900 Ω

Equipment side termination: Customer is required to supply

centre tapped 1% resistor

Insertion Loss

Drive level*: -65 dBm to +20 dBm

Drive level units: dBm, dBμV, V

Frequency range: 20 Hz to 3 MHz

Basic Accuracy**: 0 to -3 dB ±0.1 dB

*Varies with line impedance

**Varies with frequency

Return Loss

Drive level*: -60 dBm to +25dBm

Drive level units: dBm, dBμV, V

Frequency range: 20 Hz to 3 MHz

Basic Accuracy**: 0 to 25 dB ±1dB

25 to 30 dB ±2 dB

30 to 35 dB ±3 dB

*Varies with DUT impedance

**Varies with frequency

Transverse balance (analogue voiceband)

Drive level: 0 dBm (0.775 V rms)

Frequency range: 200 Hz to 10 kHz

Basic Accuracy: to 80 dB ±1 dB

Transverse balance (digital)

Drive level: 0 dBm (0.316 V rms)

Frequency range: 10 kHz to 3 MHz

Basic Accuracy:

to 55 dB ±1dB (≤1.55 MHz)

to 45 dB ±1dB (>1.55 MHz)

45 dB to 55 dB ±3 dB (>1.55 MHz)

Longitudinal balance

(analogue voiceband)

Drive level: 1 V rms

Frequency range: 200 Hz to 10 kHz

Basic accuracy: to 80 dB ±1 dB

Longitudinal balance (digital)

Drive Level: 0 dBm

FrequencyRange: 10 kHz to 3 MHz

Basic Accuracy:

to 55 dB ±1 dB (10 kHz to 1.1 MHz)

to 45 dB ±1 dB (>1.1 MHz)

45 dB to 55 dB ±3 dB (>1.1 MHz)

Total Harmonic Distortion

Maximum drive level: 6 V rms (±2%) at the DUT

Drive level units: Vrms, Vp-p, dBm

Frequencies: 150, 300, 500, 600, 5k, 10k,

15k, 20k, 25k, 30k, 40k, 50k, 100k, 150k

and 200 kHz

DC bias current

Output current: 1 to 200 mA

Step size: 0.1 mA (1 to 20mA), 1mA (20 to 200 mA)

Basic accuracy: ±1% ±1 μA (1 to 20 mA),

±1% ±10μA (20 to 200 mA)

Compliance voltage: 22.5 V (into line side termination)

Power Supply

Input voltage: 115 V AC ±10% or 230 V AC

±10% (selectable)

Frequency: 50/60 Hz

Environmental

Installation category: II (in accordance with IEC664)

Temperature range: Storage -40°C to 70°C,

Operating 0°C to 40°C. Full accuracy 15°C to 35°C.

Relative humidity: up to 80% non-condensing

Pollution degree: 2 (mainly non-conductive)

Altitude: up to 2000 m

Safety

Complies with the requirements of EN61010-1

EMC

Immunity: EN61326-1

Emissions: EN55022 Class A

Mechanical

Height: 150 mm (6″)

Width: 440 mm (17 3/8″)

Height: 520 mm (20 1/2″)

Weight: 14 kg 

聯(lián)系方式

佛山市順德區(qū)力揚(yáng)奧特自動(dòng)化設(shè)備公司

聯(lián)系人:
許軍華先生
手機(jī):
13695162069
傳真:
86 0757 22306790
所在地:
廣東省
類型:
工廠
地址:
廣東省佛山市順德區(qū)昌宏路16號(hào)

服務(wù)熱線

86 0757 22306785

提示:您在維庫(kù)儀器儀表網(wǎng)上采購(gòu)商品屬于商業(yè)貿(mào)易行為。以上所展示的信息由賣家自行提供,內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由發(fā)布賣家負(fù)責(zé),請(qǐng)意識(shí)到互聯(lián)網(wǎng)交易中的風(fēng)險(xiǎn)是客觀存在的。 請(qǐng)廣大采購(gòu)商認(rèn)準(zhǔn)帶有維庫(kù)儀器儀表網(wǎng)認(rèn)證的(金牌會(huì)員、VIP會(huì)員、至尊VIP會(huì)員、百維通)供應(yīng)商進(jìn)行采購(gòu)!
個(gè)人中心
商家電話

人工服務(wù)電話
86 0757 22306785

頂部
立即詢價(jià)
手機(jī)訪問(wèn)

掃一掃
進(jìn)入手機(jī)店鋪